Gas analysis equipments HOME   |   Product   |   Diagnostic & Test Equipments   |   Gas analysis equipments

KDGA

Features

  • Infrared photo-acoustic spectroscopy technology
  • Within 20 minutes, 7 key fault gases and   moisture can be read
  • Pure physical photo-acoustic spectroscopy   technology
  • The consumables of calibration gas and carrier   gas are needless
  • The concentration of moisture in the oil can be given during   the same one test +/- 1ppm
  • step-by-step software guides and touch screen, the user pass through   the procedure
  • International general faults gases diagnosis method, preset the warning   limits Roger's ratios. Duval's Triangle. IEEE key gases

SPECIFICATIONS

Accuracy or tolerance when valve<20ppm, ± 1ppm / while >20ppm , ± 10%
Oil sample 40ml ±2ml
Interface to PC USB
Printing output 2 inch mini printer
Input Power 100~250VAC, 4~63Hz, 12W
Dimension 524 x 428 x 206
Weight 10kg

Types of Gas analysis

Gas Range(ppm) Resolution
Hydrogen(H2) 5.0 ~ 5,000 2ppm NA
Carbon Monoxide(CO) 1.0 ~ 50,000 2ppm
Carbon Dioxide(CO2) 2.0 ~ 50,000 0.1ppm
Ethylene(C2H4) 1.0 ~ 50,000 0.1ppm
Ethane(C2H6) 1.0 ~ 50,000 0.1ppm
Methane(CH4) 1.0 ~ 50,000 0.1ppm
Acetylene(C2H2) 0.3 ~ 50,000 0.1ppm
Water(H2O) >5ppm 2ppm NA